Kilowatt hour meters single phase

The rising energy cost requires users, especially of commercial, institutional and industrial installation, to measure the energy used by individual electrical loads. These energy measurement inputs allow users to analyse and define ways to optimise their electrical equipment and reduce energy consumption.
The new range of KWH meter, EC050 and EC051, provides a simple direct reading of energy consumption in the measured single-phase circuit, from 20mA up to 32A, without the use of current transformer.

EC051 is integrated with a pulsed output for remote indication or linkage to an energy management system. The compact size of only 1 module width, ie 17.5mm, and modular din-rail design allows easy mounting into new or existing installation.

EC050

Single phase kwhmeter direct connection up to 32A

EC051

Single phase kwhmeter direct connection up to 32A with pulsed output

Environment

  • Width: 1 module – 17.5 mm.
  • Protection degree: IP20
  • Operating temperature: -10°C to +45°C

Electrical characteristics

  • Voltage supply: 230 V AC +/- 20%
  • Frequency: 50 Hz only.
  • Maximum current: 32A
  • Base current (Ib): 10A
  • Starting current :20mA
  • Resistance to current overloads: 30 x I max during 10ms.
  • Resistance to voltage overloads: 276V
  • Voltage input consumption: 0.3W / 6.7VA.
  • Current input consumption: 0.50 VA at I max.

Metering characteristics

  • Accuracy of 1% according to IEC 61036.
  • Digital display with 5+1 digits (measure of 0.1 KWH).
  • No reset
  • Savings of measurement are made regularly and in case of power failure, data will be kept in memory permanently.
  • Blinking LED (power consumption indicator) : constant at 6000 imp / KWH.
  • Pulsed output: 100 WH - 100 ms (only on EC051).

Kwh meters direct 63 A

Single-phase kilowatt hour meter (3 modules) and three-phase kilowatt hour meter (4 modules) direct 63 A.
  • EC150, single-phase, basic
  • EC152, single-phase, 2 tariffs
  • EC350, three-phase, basic
  • EC352, three-phase, 2 tariffs

In case of 2 tariff levels, the EC152 and EC352 will count separately the energy used in tariff 1 and in tariff 2.

Three-phase kwh meter direct 100 A

Three-phase kilowatt hour meter (7 modules) direct 100 A.
  • EC360, three-phase, basic
  • EC362, three-phase, 2 tariffs

In case of 2 tariff levels, the EC362 will count separately the energy used in tariff 1 and in tariff 2.

Three-phase Via CT up to 6000 A

Three-phase kilowatt hour meter Via CT (4 modules) up to 6000 A.
  • EC370, three-phase, basic
  • EC372, three-phase, 2 tariffs

In case of 2 tariff levels, the EC372 will count separately the energy used in tariff 1 and in tariff 2.